ENGINEERING SPECIFICATIONS
Accuracy: +/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +/- 50°F]
Repeatability: +/- 0.2 % of Rate
Response Time: Gases: 1 to 2 sec. Typical
Liquids: Less than 500ms
Pressure Rating: 0 - 1200 psig (Std)
0 - 10000 psig Dependent on meter size
Mass Flow Rates: Gas: 40 to 50,000 SFPM
Liquid: .02 to 20 FPS
Note: maximum determined by pipe capacity
Flow Range: 100:1 Std. Multiple ranges available
Calibrated Temperature Range: Gas: -20 F to 350 F (-28°C to 162°C )STD.
[-20°F to 1000°F] (-28°C to 538°C) Optional)
Liquid: -20F to 350F (-28°C to 162°C ) STD.
[ -20°F to 500°F](-28°C to 2691°C) Optional
Wetted Materials: 316SS (STD). Consult the factory for other material requirements
Mounting: Flange, Packing Gland, Triclover, Hot Tap
Calibration Temperature Capability: -20°F to 1000°F(-29°C to 538°C)
MICROPROCESSOR SPECIFICATIONS:
EEPROM Memory: 64K
Displays: 8 digit Flowrate and Totalizer (Optional)
Communicator: Interface: RS-232 via Ribbon Connector
Baud Rate: 9600
Filter Factor
Flow Full Scale
Flow Rate Decimal Point
Flow Totalizer Decimal Point
Flow Totalizer Flowrate Ratio
Power: 120/240 vat, 50/60 Hz.
24VDC, 1 Amp (Factory Set)
Electrical Connections:3/4” FNPT Power & Signal
Enclosure: Cast Aluminum, Epoxy Painted
Environmental Ratings: Housing: Explosion Proof, Class 1, Div. 1,
Groups, B, C D
Weatherproof: Nema 4
Ambient Temperature: -25 to 60 C (-13 to 140 F)
Storage Temperature: -40 to 70 C ( -40 to 158F )
|
Mounting: Integral to the Flow Transducer
Remote to 4000 ft., Wall or Frame mount
Signal Cable for Remote Design: 18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.
MODEL NUMBERING SYSTEM: Base Model: = 9500
Electronics Mounting: I = Integral Mount
R = Remote Mount
F = Fluid
G = Gas
L = Liquid
Probe Size: % to 2” (See Sizing Tables for Gas and Liquid).
Material: 316SS = STD
Other = Consult Factory
Process Connection: PG = Packing Gland (Std.)
FLG-150 =150# RF Flange (Std.Van stone)
TC = Triclover
FLG-Other = Consult Factory
Other = Consult Factory
Power: 24 = 22-26 VDC, 1 AMP. 4 WIRE
120 = 120VAC, 50/60 HZ (STD.)
240 = 240VAC 50/60 HZ
Output Signals: (Select One**)
0/5 = 0-5 VDC**
0/10 = 0-10 VDC**
4/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered
4/20T = Opt Process Fluid Temp. 4-20mA Self Powered
Other = Consult Factory
Display: (Optional)
ND = No Display
D = Flowrate Display, 8 Digit
8T = Totalizer
D/8T = Flowrate and Total Display, 8 digit
Signal Cable for Remote Design: SC25 = 25 FT Supplied with remote configuration
|